Carbon dioxide (CO2) is a naturally occurring substance in the atmosphere and it has been used as refrigerant since the early days of refrigeration. CO2 has zero ODP and a GWP of 1, making it one of the best choices from an environmental perspective. Due to thermodynamic properties, CO2 systems require high operating pressures in order to operate efficiently. CO2 has a low critical temperature and high pressure 31°C and 73.8bar respectively.
CO2 refrigeration cycles can be transcritical as well as subcritical. Transcritical and subcritical refers to the high-pressure side of the systems, as it operates above or below the critical point, respectively. Transcritical refers to the state of the refrigerant above the critical point.
The design pressure of CO2 systems depends on the corresponding component refrigerant state. A design pressure of 80bar is sufficient for components in contact with non-transcritical CO2 at working and standstill conditions.
TALOS® S80 tubes are specifically designed for an operation pressure of up to 80bar. In order to meet the high-pressure CO2 requirements TALOS®S80 tubes are manufactured with reinforced wall thicknesses in comparison with TALOS® ACR.
TALOS® S80 can be used where the system’s design pressure does not exceed 80bar, i.e. where the CO2 is not supercritical. In practice, this occurs at both high and low pressure sides in subcritical cycles and at the low pressure side of transcritical cycles.
The well-known installation practices of refrigeration copper tubes apply both in systems and in the field (see relative EN378 standard for guidelines).
Copper phosphorus deoxidised (Cu-DHP), having minimum copper content 99,90% and P = 0,015% – 0,040%.
TALOS®S80 for 80bar1 | |||
---|---|---|---|
Outer Diameter | Wall Thickness | ||
[inch] | [mm] | [mm] | [inch] |
5/16” | 7,94 | 0,70 | 0,028 |
3/8” | 9,53 | 0,80 | 0,031 |
1/2” | 12,70 | 0,90 | 0,035 |
5/8” | 15,88 | 1,05 | 0,041 |
3/4” | 19,05 | 1,30 | 0,051 |
7/8” | 22,23 | 1,50 | 0,059 |
1 1/8” | 28,58 | 1,90 | 0,075 |
1 3/8” | 34,93 | 2,30 | 0,091 |
1 5/8” | 41,28 | 2,70 | 0,106 |
2 1/8” | 53,98 | 3,60 | 0,142 |
2 5/8” | 66,68 | 4,50 | 0,177 |
1. Maximum Allowable Pressure calculation acc. to EN 14276:2020. For service temperatures from -196°C up to 100°C.
TALOS®S80 tubes are made from Copper-DHP (CW024A, UNS 12200). They are produced according to EN 12735-1 and internal production specifications and are approved according to the European Pressure Equipment Directive (PED) 2014/68/EU.